Prediksi Sisa Umur Transformator Berdasarkan Suhu Hotspot pada Gardu Induk Kebonagung

Authors

  • Aris Yusuf Maulana Departemen Teknik Elektro dan Informatika, Universitas Negeri Malang, Malang, Indonesia Author
  • Arif Nur Afandi Departemen Teknik Elektro dan Informatika, Universitas Negeri Malang, Malang, Indonesia Author
  • Achmad Farouq Nur Wahyu Ramadhan Departemen Teknik Elektro dan Informatika, Universitas Negeri Malang, Malang, Indonesia Author
  • Irfan Andriansyah Departemen Teknik Elektro dan Informatika, Universitas Negeri Malang, Malang, Indonesia Author

DOI:

https://doi.org/10.70716/reswara.v4i3.516

Keywords:

transformator, load curve, hotspot temperature, aging loss, remaining life prediction

Abstract

The ever-increasing demand for electrical energy has a direct impact on the workload of transformers as vital components of the power system. Overloading can accelerate transformer insulation degradation through rising hotspot temperatures, thereby shortening its service life. This study aims to predict the remaining life of 150/20 kV transformers at Kebonagung Main Substation based on loading and hotspot temperature data throughout 2025. The methods employed include loading ratio calculation, top oil temperature rise, hotspot temperature, relative thermal aging rate using the Montsinger method, and transformer aging loss. Peak load data and ambient temperature data from Malang City were used as calculation inputs. The results show that transformer 5 experienced underloading in several months (below 40%), while transformer 6 operated within an efficient loading range. The hotspot temperatures of both transformers remained below the SPLN standard limit of 98°C. The aging loss values were 0.00650 for transformer 5 and 0.11484 for transformer 6. Based on these calculations, the predicted remaining life of transformer 5 is 23.993 years, while transformer 6 is 15.923 years. These findings are expected to serve as technical references for maintenance and replacement decision-making to improve power system reliability.

Downloads

Published

2026-06-29

How to Cite

Maulana, A. Y., Afandi, A., Ramadhan, A. F. N. W. ., & Andriansyah, I. . (2026). Prediksi Sisa Umur Transformator Berdasarkan Suhu Hotspot pada Gardu Induk Kebonagung. RESWARA: Jurnal Riset Ilmu Teknik, 4(3), 171-179. https://doi.org/10.70716/reswara.v4i3.516